Sampling cooler |
SCXQ sampling cooler SCXO sampling cooler is used to sample liquid or gas with high temperature. The cooler is in characteristic of compact structure, high heat transfer efficiency, convenient cleaning and long lifetime. It is widely used in petroleum, chemical industry, light-industry and electricity departments for heating, thermo transfer. The cooler can also be a self-seal cooler of oil pump.1、Single phase sampling cooler SCXQ-IA ■Main technical specifications of single phase sampling cooler
Pipe |
Design pressure |
3.92MPa |
Shell |
Design pressure |
ATM |
Design temperature |
350℃ |
Design temperature |
60℃ |
Operating medium |
/ |
Operating medium |
Water |
Heat transfer area:0.084m2 | ■Table of single phase sampling cooler
Type |
Operating medium |
Coiler material |
Cooler orifice DN |
1 |
2 |
3 |
4 |
5 |
SCXQ-IA-1 |
Oil products |
20 |
15 |
15 |
20 |
25 |
G1/2 |
SCXQ-IA-2 |
Oil products with sulfate |
1Cr18Ni9Ti |
15 |
15 |
20 |
25 |
G1/2 |
SCXQ-IA-3 |
Oil gas |
20 |
15 |
8 |
20 |
25 |
G1/2 |
SCXQ-IA-4 |
Oil gas with sulfate、Hydrogen |
1Cr18Ni9Ti |
15 |
8 |
20 |
25 |
G1/2 | Note: SCXQ-IA-3,4 orifice with Ф8 reducer. 2、Double-connection sampling cooler SCXQ-IB ■Main technical specifications of double-connection sampling cooler
Pipe |
Design pressure |
0.58MPa |
Shell |
Design pressure |
0.58MPa |
Design temperature |
172℃ |
Design temperature |
60℃ |
Operating medium |
Steam、water |
Operating medium |
Water |
Heat transfer area:1.04m2 | ■Table of double-connection sampling cooler
NO. |
Description |
Quantity |
DN |
PN |
Remark |
1 |
Steam inlet |
2 |
10 |
PN |
|
2 |
Steam outlet |
2 |
10 |
/ |
|
3 |
Cooling water inlet |
1 |
40 |
/ |
|
4 |
Cooling water outlet |
1 |
40 |
2.0 |
|
5 |
Drain |
1 |
50 |
2.0 |
|
6 |
Up vent |
2 |
G1/2 |
/ |
with pipe plug |
7 |
Down vent |
2 |
G1/2 |
/ |
with pipe plug | 3、Four-connection sampling cooler SCXQ-IC■Main technical specifications of Four connection sampling cooler
Pipe |
Design pressure |
4.62MPa |
Shell |
Design pressure |
0.58MPa |
Design temperature |
275℃ |
Design temperature |
60℃ |
Operating medium |
Steam、water |
Operating medium |
Water |
Heat transfer area:2.08m2 |
NO. |
Description |
Quantity |
DN |
PN |
Remark |
1 |
Steam inlet |
4 |
10 |
PN |
|
2 |
Steam outlet |
4 |
10 |
/ |
|
3 |
Cooling water inlet |
1 |
40 |
/ |
|
4 |
Cooling water outlet |
1 |
40 |
2.0 |
|
5 |
Drain |
1 |
50 |
2.0 |
|
6 |
Up vent |
2 |
G1/2 |
/ |
with pipe plug |
7 |
Down vent |
2 |
G1/2 |
/ |
with pipe plug |
|
|